More than half of them do not happen at the crushing end but at the lubrication end — keep the oil circuit clean and the machine is already mostly steady.
Match the oil-pump group first: a violent knocking noise from the pump means misalignment between pump and motor, an eccentric pin slot in the coupling half, or too thick oil. A hot pump means a blocked suction line or worn gears. The pump runs but pressure is short — inaccurate gauge or a blocked return line. Temperature is the most sensitive signal: return-oil temperature above 60 °C points to abnormal friction on the eccentric bushing faces or a bearing in trouble; oil leaving the cooler above 45 °C means insufficient cooling water or a blocked cooling circuit; water in the tank, or oil in the water, means a burst tube inside the cooler.
Then one line each for filtering and cooling water: a pressure difference across the filter above 40 kPa means a clogged or torn screen; cooling-water pressure must run 50 kPa below the oil pressure — let water pressure exceed oil pressure and water seeps into the oil. Three mechanical faults: a violent crack and the moving cone stops while the pulley keeps turning — broken main shaft; violent knocking while crushing — loose moving-cone liner; pulley turning but the cone not — damaged key teeth or a sheared safety pin.
Shuangjin's SK series gyratory sets a measuring point at each of these locations, so oil temperature, oil pressure and differential pressure all have their own readings and faults are easy to localise. Do you keep a daily record of your gyratory's return-oil temperature?
Applicable models: Shuangjin SK series hydraulic gyratory crushers
Related product: SK hydraulic gyratory crusher
Ask us directly. If it is a question we are asked often, it becomes the next article — and you get the answer either way.